Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38685313
2.
J Vasc Surg ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38552884

RESUMEN

OBJECTIVE: This study aims to report the efficacy and safety of double-fenestrated physician-modified endovascular grafts (PMEGs) for total aortic arch repair with at least 3 years of follow-up. METHODS: All consecutive patients with a pathological aortic arch who underwent aortic arch repair combined with a homemade double-fenestrated stent graft from 2017 to 2020 were reviewed. RESULTS: 74 patients were treated for pathological arch conditions with a double-fenestrated PMEG. Of these, 81% were male, the mean age was 69.9 years, and 59% were classified as American Society of Anesthesiology 3 or 4. Thirty-five percent were treated for a postdissection aneurysm, 36% for a degenerative aneurysm, and 14% for acute type B dissection. Fifteen percent had supra-aortic trunk dissection. Fenestration on the subclavian artery was performed in 96%; if not, a carotid-subclavian bypass was carried out. Technical success was 100%. The proximal landing zone is consistently in zone 0. Early outcomes revealed a 3% occurrence of type 1 endoleak, which was successfully treated by prompt reintervention. One retrograde dissection occurred, and one patient died from hemorrhage on an iliac conduit. A 5% stroke rate was reported. During long-term follow-up (mean time 40.7 months), one type 1 endoleak appeared and was successfully treated; no type 2 or type 3 endoleak requiring intervention occurred. No stent fractures or migrations were reported. Four percent of patients required reintervention, but no surgical conversion to open surgical repair was needed on the aortic arch. No patient died from a cause related to the main procedure. CONCLUSIONS: Total aortic arch repair with double-fenestrated PMEGs is associated with acceptable early and midterm major morbidity and mortality. It is suitable for the main aortic pathologies. Moreover, it is easily available for emergency situations.

3.
J Surg Res ; 295: 222-230, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38039727

RESUMEN

INTRODUCTION: Study aims were to evaluate the elastic properties of vascular substitutes frequently used for pulmonary artery (PA) replacement, and then to compare their compliance and stiffness indexes to those of human PA. METHODS: A bench-test pulsatile flow experiment was developed to perfuse human cadaveric vascular substitutes (PA, thoracic aorta, human pericardial conduit), bovine pericardial conduit, and prosthetic vascular substitutes (polytetrafluorethylene and Dacron grafts) at a flow and low pulsed pressure mimicking pulmonary circulation. Intraluminal pressure was measured. An ultrasound system with an echo-tracking function was used to monitor vessel wall movements. The diameter, compliance, and stiffness index were calculated for each vascular substitute and compared to the human PA at mean pressures ranging from 10 to 50 mmHg. RESULTS: The compliance of the PA and the thoracic aorta were similar at mean physiological pressures of 10 mmHg and 20 mmHg. The PA was significantly less compliant than the aorta at mean pressures above 30 mmHg (P = 0.017). However, there was no difference in stiffness index between the two substitutes over the entire pressure range. Compared to the PA, human pericardial conduit was less compliant at 10 mmHg (P = 0.033) and stiffer at 10 mmHg (P = 0.00038) and 20 mmHg (P = 0.026). Bovine pericardial conduit and synthetic prostheses were significantly less compliant and stiffer than the PA for mean pressures of 10, 20, and 30 mmHg. There were no differences at 40 and 50 mmHg. CONCLUSIONS: Allogenic arterial grafts appear to be the most suitable vascular substitutes in terms of compliance and stiffness for PA replacement.


Asunto(s)
Arteria Pulmonar , Humanos , Animales , Bovinos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Ultrasonografía , Flujo Pulsátil
4.
J Endovasc Ther ; : 15266028231215779, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38049943

RESUMEN

OBJECTIVE: The aim of this study is to report the efficiency and safety of single-fenestrated physician-modified endografts (PMEGs) in zone 2 aortic arch pathologies with at least 3 years of follow-up. METHODS: All consecutive patients with a pathological aortic arch who underwent aortic repair combined with homemade single-fenestrated stent-graft from 2015 to 2020 were reviewed. The patients with a target vessel different from the left subclavian artery (LSA) were excluded. RESULTS: A total of 63 patients were treated for a pathological arch in zone 2 with a single-fenestrated PMEG. 73% were male, and the mean age was 65 years old. 25% were treated for a degenerative aneurysm, 19% for a post dissection aneurysm and 24% for an acute type B dissection. 52% of the patients were treated as an emergency and half of those for an aortic rupture. The LSA fenestration was stented in 70%. During 30 days of follow-up, 2 strokes (3%) were reported, 6 patients (10%) died with 4 of those treated for aortic rupture and 1 had a retrograde aortic dissection. During at least 3 years of follow-up (median 49 months), no reintervention was needed for endoleaks, there was no stent fracture or stent migration. No patient died from an aortic cause. Subgroup analysis comparing the endovascular treatment for various aortic pathologies did not find significant differences in death rate or comorbidity including stroke. When comparing emergent and elective aortic repair, operating time was similar (64 vs 65 minutes), and the LSA fenestration was less frequently stented (52%) in the emergency group. There was no difference in stroke frequency. There was a higher rate of death in the emergency group at 30 days of follow-up, but no patient died from aortic cause in the long-term follow-up. CONCLUSIONS: Aortic arch repair with single-fenestrated PMEGs for zone 2 pathological arch disease is associated with acceptable early and midterm major morbidity and mortality. It is suitable for emergency situations. CLINICAL IMPACT: Single-fenestrated PMEG for the left subclavian artery is a safe and efficient option in the short and medium term for the treatment of the aortic arch in zone 2 with 98% technical success. It allows for aortic repair and subclavian artery revascularization in a single step for all patients. It is suitable for a range of main pathologies, including degenerative, dissection-related, isthmus rupture, and embolic pathologies. Additionally, it is always available and easily utilized in emergency cases.

5.
Cancers (Basel) ; 15(20)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37894338

RESUMEN

BACKGROUND: The aim of this single-center retrospective cohort study was to assess the impact of arterial reconstruction technique on lung perfusion. The second objective was to ascertain the functional validity of arterial sleeve lobectomy. METHOD: Between January 2001 and December 2020, a total of 81 patients underwent lobectomy with pulmonary artery (PA) reconstruction for lung cancer at the University Hospital of Montpellier. After excluding patients with an incomplete postoperative pulmonary function test, we conducted a comparative analysis of the preoperative and postoperative functional outcomes (FEV1) of 48 patients, as well as the preoperative and postoperative Technetium99m scintigraphic pulmonary perfusion results of 28 patients. Then, we analyzed postoperative perfusion results according to the pulmonary artery reconstruction techniques use. RESULTS: PA reconstruction types were as follows: 9 direct angioplasties (19%), 14 patch angioplasties (29%), 7 end-to-end anastomoses (15%), 6 prosthetic bypasses (12%), 11 arterial allograft bypasses (23%), and 1 custom-made xenopericardial conduit bypass. Regardless of the type of vascular reconstruction performed, the comparative analysis of lung perfusion revealed no significant difference between the preoperative and postoperative perfusion ratio of the remaining parenchyma (median = 29.5% versus 32.5%, respectively; p = 0.47). Regarding the pulmonary functional test, postoperative predicted FEV1 significantly underestimated the actual postoperative measured FEV1 by about 260 mL (11.4%) of the preoperative value. The patency rate was 96% and the 5-year overall survival was 49% for a mean follow up period of 34 months. CONCLUSION: Lobectomy with PA reconstruction is a valid parenchymal-sparing technique in terms of perfusion and respiratory function.

6.
J Endovasc Ther ; : 15266028231202234, 2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37752861

RESUMEN

OBJECTIVE: The aim of this case series is to report feasibility, efficiency, and safety of fenestrated physician-modified endografts (PMEGs) in aortic arch pathologies with aberrant right subclavian artery (ARSA) and/or Kommerell's diverticulum (KD). METHODS: All consecutive patients with ARSA and/or KD who underwent hybrid aortic arch repair combined with homemade fenestrated stent-graft from 2018 to 2022 were reviewed. RESULTS: Six patients with ARSA and/or KD underwent hybrid surgery for aortic repair, 4 of whom were men, with a mean age of 49 years. Furthermore, 2 of them were symptomatic with dysphagia, 1 was taken in emergency, 1 had a bovine arch and a KD, and 2 had right descending thoracic aortas. The mean operation time was 138 (111-216) minutes. In addition, 83% of the homemade grafts were double fenestrated. All the proximal landings were in zone 0; the mean proximal aortic diameter was 29 (23-34) mm. The range of diameters for the endografts were 24 to 38 mm. There was a 100% technical success, with 0% 30 days mortality, no stroke, and no endoleak. During the follow-up, no aortic-related death or secondary intervention was required and all supra-aortic vessels remain patent. CONCLUSION: Hybrid aortic arch repair, with fenestrated PMEGs for ARSA and/or KD, is associated with acceptable early and midterm major morbidity and mortality. CLINICAL IMPACT: This retrospective case series analyzed outcomes in 6 patients with an aberrant right subclavian artery and/or Kommerell's diverticulum treated with fenestrated PMEGs during an average 16 month follow-up. The case series suggests that the use of these fenestrated PMEGs for the management of patients with an aberrant right subclavian artery is a safe, effective and durable method in the medium-term.

7.
Cancers (Basel) ; 15(2)2023 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-36672363

RESUMEN

Objectives: This study aims to evaluate the perioperative and oncologic outcomes of thoracoscopic lobectomy for advanced stage III NSCLC. Methods: We retrospectively reviewed 205 consecutive patients who underwent VATS or open lobectomy for clinical stage III lung cancer between January 2013 and December 2020. The perioperative and oncologic outcomes of the two approaches were compared. Long-term survival was assessed using the Kaplan−Meier estimator. Propensity score-matched (PSM) comparisons were used to obtain a well-balanced cohort of patients undergoing VATS and open lobectomy. Results: VATS lobectomy was performed in 77 (37.6%) patients and open lobectomy in 128 (62.4%) patients. Twelve patients (15.6%) converted from VATS to the open approach. PSM resulted in 64 cases in each group, which were well matched according to twelve potential prognostic factors, including tumor size, histology, and pTNM stage. Between the VATS and the open group, there were no significant differences in unmatched and matched analyses, respectively, of the overall postoperative complications (p = 0.138 vs. p = 0.109), chest tube duration (p = 0.311 vs. p = 0.106), or 30-day mortality (p = 1 vs. p = 1). However, VATS was associated with shorter hospital stays (p < 0.0001). The five-year overall survival (OS) and five-year Recurrence-free survival (RFS) were comparable between the VATS and the open groups. There was no significant difference in the recurrence pattern between the two groups in both the unmatched and matched analyses. Conclusion: For the advanced stage III NSCLC, VATS lobectomy achieved equivalent postoperative and oncologic outcomes when compared with open lobectomy without increasing the risk of procedure-related locoregional recurrence.

8.
Ann Vasc Surg ; 90: 100-108, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36270548

RESUMEN

BACKGROUND: Obtaining a suitable proximal landing zone in blunt thoracic aortic injuries (BTAI) often necessitates coverage of the left subclavian artery (LSA). This study aimed to evaluate the outcomes of physician-modified endovascular grafts (PMEGs) in this indication. METHODS: We performed a retrospective analysis of a prospective registry including all patients who had undergone a thoracic endovascular aortic repair (TEVAR) for BTAI from October 2008 to October 2020. Starting in 2015, patients requiring coverage of the LSA were either treated using a physician-modified proximal scalloped or single-fenestrated stent graft. After an early postoperative computed tomography scan, follow-up was performed at 3 months, 6-months, and yearly. RESULTS: Among 58 patients treated with TEVAR for BTAI, 23 (39.6%) patients required a zone 2 landing zone of which 10 (17.2%) patients were treated with PMEGs. The median age was 48 [31-64.5] years, and 78.2% (n = 18) patients were male. The median Injury Severity Score was 38 [27-55.5]. Coverage of the LSA was performed in 25.8% (n = 15) of the total population in which 5 patients had an LSA transposition. The median modification time was 18 [14-27] minutes. Technical success of PMEGs was 90.0% overall and 100% for fenestrated stent grafts. No stroke, paraplegia, or retrograde dissection was observed. The primary patency of the LSA in the PMEGs group was 90 % at 1 year and 28.8 % in the LSA coverage group (P < 0.01). CONCLUSIONS: The use of PMEGs is feasible and effective in the management of BTAI with a short proximal landing zone. Further evaluation of long-term outcomes and durability are awaited.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Stents , Estudios Retrospectivos , Resultado del Tratamiento , Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos
9.
J Endovasc Ther ; 30(1): 151-155, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35094606

RESUMEN

PURPOSE: The purpose of the study was to demonstrate the feasibility of urgent endovascular treatment of a traumatic aortic isthmus rupture in a patient with an aberrant right subclavian artery. CASE REPORT: A 23-year-old man was admitted to a regional trauma center after a motor vehicle collision and found to have cerebral trauma and a large pseudoaneurysm of the aortic arch. Trauma computed tomography (CT) identified a blunt traumatic thoracic aortic injury with an aortic false aneurysm in the context of an aberrant right subclavian artery. A hybrid repair was performed with bilateral subclavian carotid bypasses and a double fenestrated physician-modified stent graft. The patient had an uneventful postoperative course. Postoperative CT scan showed sealing of the aortic arch rupture and patency of all the supra-aortic trunks. CONCLUSION: Endovascular repair of blunt traumatic thoracic aortic injury is considered first-line therapy. Aortic arch anomalies add complexity to treatment. This report demonstrates that a hybrid strategy with bilateral carotid-axillary bypasses and homemade double fenestrated endograft of the aortic arch is a valuable approach for this challenging emergency in the context of an aberrant right subclavian artery.


Asunto(s)
Aneurisma de la Aorta Torácica , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Adulto Joven , Adulto , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Procedimientos Endovasculares/métodos , Stents , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/cirugía
10.
J Endovasc Ther ; : 15266028221116747, 2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35927926

RESUMEN

OBJECTIVE: The aim was to evaluate early and medium-term outcomes of double fenestrated physician-modified endovascular grafts for total endovascular aortic arch repair. METHODS: This single-center retrospective analysis of prospectively-collected data included 100 patients, from January 2017 to December 2021, undergoing thoracic endovascular aortic repair (TEVAR) for zone 0. The fenestrations were a proximal larger fenestration that incorporated the brach2iocephalic trunk and left common carotid artery and a distal smaller fenestration for the left subclavian artery (LSA). Only the LSA fenestration was stented. RESULTS: The median duration for stent-graft modification was 23±6 minutes. Of the 100 patients, 70 were men. The mean patient age was 70±10.5 years. Indications for treatment included degenerative aortic arch aneurysm (n=32), dissecting aortic arch aneurysm after type A dissections (n=23) and (n=19) after type B dissections, acute complicated type B dissection (n=16), and other pathologies (n=10). Technical success rate was 97%. The 30 day mortality was 2% (n=2). Four patients (4%) had minor stroke with full recovery. One patient (1%) had a type IA endoleak, 1 patient (1%) had a type IB endoleak, and 2 patients (2%) have a type II endoleak from the LSA. Eight patients (8%) required reintervention: 1 type IA endoleak, 1 type IB endoleak, 1 retrograde type A dissection, and 5 because of access-related complications. During a mean follow-up of 24±7.2 months, there were no aortic rupture, paraplegia, and all supra-aortic trunks were patent. CONCLUSIONS: Double homemade fenestrated TEVAR is both feasible and effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The long-term durability will need to be assessed in studies with long-term follow-up. CLINICAL IMPACT: Double homemade fenestrated TEVAR is effective for total endovascular aortic arch repair avoiding the need for anatomical and extra-anatomical surgical revascularization. The standout feature of this double fenestrated device is its simple handling during operation with the proximal fenestrations being directed to the orifices of the BT and LCCA automatically when the LSA fenestration is catheterized and secured by covered stent placement. The deployment algorithm actively steers the operator away from superfluous manipulations of the device within the arch and avoids guidewire manipulation in carotid arteries. The long-term durability will need to be assessed in studies with long-term follow-up.

11.
J Vasc Surg ; 76(5): 1133-1140.e2, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35697312

RESUMEN

OBJECTIVE: We evaluated the early- and medium-term outcomes of single- and double-fenestrated physician-modified endovascular grafts (PMEGs) for total endovascular degenerative aortic arch aneurysm repair. METHODS: We performed a single-center, retrospective analysis of prospectively collected data from 52 patients from August 2013 through January 2021 who had undergone homemade fenestrated thoracic endovascular aortic repair for degenerative aortic aneurysms. In all cases, a distal smaller fenestration for the left subclavian artery (LSA) was fashioned and was the only one stented. For a double-fenestrated endograft, a proximal larger fenestration that incorporated both the brachiocephalic trunk and the left common carotid artery was added. RESULTS: A total of 52 patients with degenerative aortic arch aneurysms were treated. Of the 52 patients, 36 were men, the mean age was 75 ± 8 years, 31% had received a single LSA fenestration, and 69% had undergone double-fenestrated thoracic endovascular aortic repair. Of the 52 procedures, 5 (10%) were emergent procedures. The technical success was 100%. The median time required for stent graft modification was 22 ± 6 minutes. The 30-day mortality was 2% (n = 1). Five patients (10%) had experienced a cerebrovascular event, including two transient ischemic attacks, one minor stroke with full neurologic recovery, and two with sequelae. Two patients (4%) had experienced perioperative retrograde dissection during follow-up. No patient had developed a type I, II, or III endoleak from the LSA. No patient had required reintervention. All supra-aortic trunks were patent. During a mean follow-up of 18 ± 11 months, no patient had required conversion to open surgical repair, aortic rupture, or paraplegia. CONCLUSIONS: Single or double PMEG is a safe and suitable tool for the treatment of high morbidity pathology such as aortic arch degenerative aneurysm repair. In addition, this device can be used in patients requiring elective or emergency repair.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Disección Aórtica/cirugía , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Complicaciones Posoperatorias/terapia , Factores de Riesgo , Factores de Tiempo , Stents/efectos adversos , Aneurisma de la Aorta/cirugía
12.
J Surg Res ; 276: 416-432, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35465975

RESUMEN

INTRODUCTION: The use of video-assisted thoracoscopic surgery (VATS) lobectomy has become a mainstay of modern thoracic surgery practice and the technique of choice for resection of early-stage lung cancers. However, the benefits of VATS following induction therapy are yet to be clarified. This study aims to assess whether VATS lobectomy achieves similar perioperative and oncologic outcomes compared to thoracotomy for nonsmall cell lung cancer after induction therapy. METHODS: We retrospectively reviewed the outcomes of 72 patients who underwent lung lobectomy after induction therapy in our institution from January 2017 to January 2020. Subsequently, we carried out a comprehensive literature search and pooled our results with available data from previously published studies to perform a meta-analysis. RESULTS: VATS was associated with reduced intraoperative blood loss (P = 0.05) and less perioperative complications (P = 0.04) in our local institution. The meta-analysis comprised nine studies. A total of 943 patients underwent VATS and 2827 patients underwent open lobectomy. VATS was associated with significant shorter surgery duration (P < 0.0001), shorter chest-tube drainage duration (P < 0.0001), and shorter hospital stays (P < 0.0001). Furthermore, there was significantly less perioperative complications (P = 0.006) and less intraoperative blood loss (P = 0.036) in the VATS group. However, there were no significant differences in 3-y overall survival and 3-y disease-free survival rates. CONCLUSIONS: In some selected patients undergoing induction therapy, VATS lobectomy could achieve equivalent perioperative outcomes to thoracotomy but evidence is lacking on oncologic outcomes. Further trials with a focus on oncologic outcomes and longer follow-up are required.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Pérdida de Sangre Quirúrgica , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Humanos , Quimioterapia de Inducción , Neoplasias Pulmonares/cirugía , Neumonectomía/métodos , Estudios Retrospectivos , Cirugía Torácica Asistida por Video/métodos , Toracotomía/métodos
13.
J Endovasc Ther ; 29(6): 921-928, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35012391

RESUMEN

PURPOSE: Carotid artery stenting (CAS) appears as a promising alternative treatment to carotid endarterectomy for radiation therapy (RT)-induced carotid stenosis. However, this is based on a poor level of evidence studies (small sample size, primarily single institution reports, few long-term data). The purpose of this study was to report the long-term outcomes of a multicentric series of CAS for RT-induced stenosis. METHODS: All CAS for RT-induced stenosis performed in 11 French academic institutions from 2005 to 2017 were collected in this retrospective study. Patient demographics, clinical risk factors, elapsed time from RT, clinical presentation and imaging parameters of carotid stenosis were preoperatively gathered. Long-term outcomes were determined by clinical follow-up and duplex ultrasound. The primary endpoint was the occurrence of cerebrovascular events during follow-up. Secondary endpoints included perioperative morbidity and mortality rate, long-term mortality rate, primary patency, and target lesion revascularization. RESULTS: One hundred and twenty-one CAS procedures were performed in 112 patients. The mean interval between irradiation and CAS was 15 ± 12 years. In 31.4% of cases, the lesion was symptomatic. Mean follow-up was 42.5 ± 32.6 months (range 1-141 months). The mortality rate at 5 years was 23%. The neurologic event-free survival and the in-stent restenosis rates at 5 years were 87.8% and 38.9%, respectively. Diabetes mellitus (p=0.02) and single postoperative antiplatelet therapy (p=0.001) were found to be significant predictors of in-stent restenosis. Freedom from target lesion revascularization was 91.9% at 5 years. CONCLUSION: This study showed that CAS is an effective option for RT-induced stenosis in patients not favorable to carotid endarterectomy. The CAS was associated with a low rate of neurological events and reinterventions at long-term follow-up.


Asunto(s)
Estenosis Carotídea , Reestenosis Coronaria , Endarterectomía Carotidea , Humanos , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/terapia , Stents/efectos adversos , Estudios Retrospectivos , Constricción Patológica , Reestenosis Coronaria/complicaciones , Resultado del Tratamiento , Recurrencia , Factores de Tiempo , Endarterectomía Carotidea/efectos adversos , Factores de Riesgo , Arterias Carótidas
14.
Interact Cardiovasc Thorac Surg ; 34(1): 74-80, 2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-34999810

RESUMEN

OBJECTIVES: This article aims to evaluate the feasibility and safety of a hybrid video-assisted thoracic surgery (VATS) approach to achieve en bloc lobectomy and spinal resection for non-small-cell lung cancer (NSCLC). METHODS: Between October 2015 and November 2020, 10 patients underwent VATS anatomical lobectomy and en bloc chest wall and spinal resection through a limited posterior midline incision as a single operation for T4 (vertebral involvement) lung cancer. Nine patients had Pancoast syndrome without vascular involvement and 1 patient had NSCLC of the right lower lobe with invasion of T9 and T10. RESULTS: There were 5 men and 5 women. The mean age was 61 years (range: 47-74 years). Induction treatment was administered to 9 patients (90%). The average operative time was 315.5 min (range: 250-375 min). The average blood loss was 665 ml (range: 100-2500 ml). Spinal resection was hemivertebrectomy in 6 patients and wedge corpectomy in 4 patients. Complete resection (R0) was achieved in all patients. The average hospitalization stay was 14 days (range: 6-50 days). There was no in-hospital mortality. The mean follow-up was 32.3 months (range: 6-66 months). Six patients (60%) are alive without recurrence. CONCLUSIONS: VATS is feasible and safe to achieve en bloc resection of NSCLC inviding the spine without compromising oncological efficacy. Further experience and longer follow-up are needed to determine if this approach provides any advantages over thoracotomy.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Cirugía Torácica Asistida por Video , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Femenino , Humanos , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Síndrome de Pancoast , Neumonectomía/efectos adversos , Cirugía Torácica Asistida por Video/efectos adversos , Vértebras Torácicas
15.
J Endovasc Ther ; 29(5): 773-779, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34955055

RESUMEN

PURPOSE: This study assessed morphological changes in the aortic true and false lumens during follow-up of patients undergoing TEVAR (Thoracic Endovascular Aortic Repair) for complicated acute and subacute type B dissection. The study analyzes the effectiveness of TEVAR in preventing distal aneurysmal progression. MATERIALS AND METHODS: All patients between 2009 and 2019 undergoing TEVAR for complicated acute and subacute type B dissection at the study institution were retrospectively reviewed. Maximal diameters were measured on the proximal descending aorta right below the left subclavian artery, thoraco-abdominal junction right above the celiac trunk, and infrarenal aortic right above the inferior mesenteric artery, pre-operatively and during follow-up, analyzing either expansion or shrinkage of true and false lumens at these 3 sites. RESULTS: Forty-one patients were included. Thirty-day incidence of death, stroke, paraplegia, and visceral ischemia was, respectively, 8% (n = 4), 6% (n = 3), 2% (n = 1), and 2% (n = 1). Three patients (6%) died from intervention-related cause. Mortality was 17% (n = 8) during a mean follow-up of 54 months. One patient had aneurysmal dilation of the descending aorta needing additional coverage and only 2 (4%) developed thoraco-abdominal aneurysms requiring re-intervention. In the remaining patients, both significant expansion of the true lumen and shrinkage of false lumen were observed at all 3 sites. CONCLUSION: Proximal coverage of the main entry tear appears to prevent aneurysmal progression in most patients (96%). With such promising results, TEVAR should be considered as a first-line treatment in acute and subacute type B dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Abdominal/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
17.
Interact Cardiovasc Thorac Surg ; 32(6): 942-949, 2021 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-34047348

RESUMEN

OBJECTIVES: The critical step in total endovascular aortic arch repair is to ensure alignment of fenestrations with, and thus maintenance of flow to, supra-aortic trunks. This experimental study evaluates the feasibility and accuracy of a double-fenestrated physician-modified endovascular graft [single common large fenestration for the brachiocephalic trunk and left common carotid artery and a distal small fenestration for left subclavian artery (LSA) with a preloaded guidewire for the LSA] for total endovascular aortic arch repair. METHODS: Eight fresh human cadaveric thoracic aortas were harvested. Thoracic endografts with a physician-modified double fenestration were deployed for total endovascular aortic arch repair in a bench test model. A guidewire was preloaded through the distal fenestration for the LSA. All experiments were undertaken in a hybrid room under fluoroscopic guidance with subsequent angioscopy and open evaluation for assessment. RESULTS: Mean aortic diameter in zone 0 was 31.3 ± 3.33 mm. Mean duration for stent graft modification was 20.1 ± 5.8 min. Mean duration of the procedure was 24 ± 8.6 min. The Medtronic Valiant Captivia stent graft was used in 6 and the Cook Alpha Zenith thoracic stent graft in 2 cases. LSA catheterization was technically successful with supra-aortic trunk patency in 100% of cases. CONCLUSIONS: The use of a double-fenestrated stent graft with a preloaded guidewire appears to be a useful technical addition to facilitate easy and correct alignment of stent graft fenestrations with supra-aortic trunk origins.


Asunto(s)
Aorta Torácica , Implantación de Prótesis Vascular , Stents , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Médicos , Diseño de Prótesis , Resultado del Tratamiento
18.
Ann Vasc Surg ; 70: 570.e1-570.e5, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32976947

RESUMEN

Despite a low-incidence extracranial carotid artery aneurysm (ECAA) disease has important clinical repercussion that obliges understanding and knowledge of correct treatment. The 2 dominant etiologies are atherosclerotic degeneration and pseudoaneurysm. The natural history of ECAAs is understood. Neck pain, a pulsatile mass and central or peripheral neurological manifestations are the most common symptoms. Recommendations for diagnosis and treatment are not uniform and still under discussion, representing a challenge for clinicians. We discuss a case of 2.5 cm asymptomatic saccular atherosclerotic ECAA treated surgically in light of the most recent literature.


Asunto(s)
Aneurisma/cirugía , Enfermedades de las Arterias Carótidas/cirugía , Arteria Carótida Interna/cirugía , Aneurisma/diagnóstico por imagen , Aneurisma/fisiopatología , Enfermedades Asintomáticas , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/fisiopatología , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/fisiopatología , Femenino , Humanos , Persona de Mediana Edad , Flujo Sanguíneo Regional , Resultado del Tratamiento
19.
Ann Surg Oncol ; 28(2): 1106-1108, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32588265

RESUMEN

BACKGROUND: Resectability of pancreatic carcinoma (PC) is directly linked to vascular extension (Tempero MA et al. in J Natl Compr Canc Netw 15(8):1028-1061, 2017. https://doi.org/10.6004/jnccn.2017.0131 ; Isaji S et al. in Pancreatology 18(1):2-11, 2018. https://doi.org/10.1016/j.pan.2017.11.011 ). Involvement of the celiac axis (CA) is typically a contraindication to surgery. High postoperative morbidity and subsequent poor prognosis have been observed in this case, especially for contact > 180° requiring arterial resection (Tempero MA et al. 2017). Recent medical advances in PC treatment, such as FOLFIRINOX-based chemotherapy eventually followed by chemoradiation therapy, offer the potential to select tumour for surgery and to obtain a negative-margin resection even in case of unresectable PC at diagnosis (Suker M et al. in Lancet Oncol 17(6):801-10, 2016. https://doi.org/10.1016/s1470-2045(16)00172-8 ; Pietrasz D et al. in Ann Surg Oncol 26(1):109-117, 2019. https://doi.org/10.1245/s10434-018-6931-6 ). A major pathologic response has been observed in more than 20% of patients after this treatment and is associated with an improved survival (Suker M et al. 2016; Pietrasz D et al. 2019). This evolution allows aggressive surgical strategies with the possibility of long-term disease control for patients showing a good response to induction treatment. PATIENT: This video presents the case of a 66-year-old man diagnosed with a locally advanced ductal adenocarcinoma of the pancreatic body with a 360° involvement of the CA and the hepatic artery. After eight courses of FOLFIRINOX chemotherapy and a capecitabin-based chemoradiation, a surgical exploration was planned for potential resection. TECHNIQUE: The key steps of the procedure are presented, i.e. surgical exposition, assessment of resectability with frozen sections of peri-arterial tissues, en bloc resection (Strasberg SM et al. in Surgery 133(5):521-527, 2003. https://doi.org/10.1067/msy.2003.146 ), and primary end-to-end arterial reconstruction. CONCLUSION: A modified Appleby operation for locally advanced PC is a technically challenging but feasible procedure in experienced teams. It offers the possibility of en bloc R0 resection of a locally advanced PC with the potential of long-term disease local control. This video may help surgeons to perform this complex intervention.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Adenocarcinoma/cirugía , Anciano , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Fluorouracilo , Humanos , Irinotecán , Leucovorina , Masculino , Oxaliplatino , Pancreatectomía , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas
20.
Ann Vasc Surg ; 71: 48-55, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32927033

RESUMEN

BACKGROUND: Retrograde type A dissection (RTAD) after zone 0 hybrid aortic arch repair is highly lethal and not infrequent complication. The aim of this study was to assess the safety and effectiveness of rapid cardiac pacing as an adjunctive tool to prevent RTAD during or after hybrid procedures for zone 0 disease. METHODS: We performed a retrospective review of 42 consecutive patients with zone 0 hybrid aortic arch repair between November 2004 and January 2018. Right ventricular pacing was carried out through unipolar electrodes attached to the epicardium of the right ventricle through the sternotomy (the indifferent electrode was in the subcutaneous tissue). Pacing was utilised during the clamping of the ascending aorta, release of the aortic clamp, and stent-graft deployment. RESULTS: Operative indications were aortic arch aneurysm 45% (n = 19), aortic arch dissection 45% (n = 19), traumatic rupture of isthmus 7% (n = 3), and type IA endoleak 2% (n = 1). Urgent procedures 48% (n = 20). The mean proximal aortic diameter was 34.14 ± 2.9 mm. Mean stent-graft oversizing was 12.97 ± 3.4%. The 30-day mortality rate was 14% (n = 6). RTAD was observed in 7% (n = 3). The actuarial survival rate was 74% over a mean follow-up of 50 ± 30.2 months. Since January 2013, rapid right ventricular pacing (overdrive pacing at a rate of 200 beats/min) was systematically used (n = 24). No RTAD was observed in this group of patients. Rapid right ventricular pacing reduced significatively the risk of RTAD (P = 0.038). CONCLUSIONS: Rapid right ventricular pacing is an effective method of inducing hypotension and appears to decrease the risk of retrograde type A dissection after zone 0 hybrid aortic arch repair.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias/prevención & control , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Endofuga/diagnóstico por imagen , Endofuga/mortalidad , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...